Product Manual
Installation (continued)
9
Step Three: Connect pump to battery or 12V supply
WARNING
Batteries are hazardous because they contain caustic acid, can emit explosive gases, and can
cause electric shock.
Caution must be exercised when making connections to a battery to avoid shock and contact with
the acid, and to prevent any sparking that could lead to an explosion.
ALWAYS follow the safety instructions and steps listed below in exact sequence when
connecting the pump to the battery terminals.
1. Preparatory
safety
Preparatory safety steps:
ALWAYS use eye protection
NEVER smoke or work near sparks or other sources of ignition.
NEVER touch both battery terminals at the same time or with any
non-insulated tools.
If battery acid contacts skin or clothing, flush immediately with water
and neutralize with baking soda.
2. Electrical
requirements
The pump should be on a dedicated (individual) circuit, controlled
with a double pole switch (UL/CSA certified) rated at or above the
fuse ampere indicated by the pump motor label. Depending on
distance of the power source from the pump and ampere load on the
circuit, wire may need to be heavier than indicated by the chart.
The pump is protected with a fuse. Use an approved wire of the size
specified or heavier.
Voltage
Model
Fuse
(amp)
Wire Leads
Wire Size
(Stranded MTW)
12 VDC
2681042
5.0
RED (positive +)
BLACK (negative -)
#14 AWG (2.5mm
2
)
(or heavier)
12 VDC
2682271
2682272
15.0
RED (positive +)
BLACK (negative -)
#14 AWG (2.5mm
2
)
(or heavier)
12 VDC
2683061
2683062
2684061
2684062
15.0
RED (positive +)
BLACK (negative -)
#14 AWG (2.5mm
2
)
(or heavier)
12 VDC
2685561
2685562
20.0
RED (positive +)
BLACK (negative -)
#14 AWG (2.5mm
2
)
(or heavier)
12 VDC
2687061
2687062
25.0
RED (positive +)
BLACK (negative -)
#12 AWG (4.0mm
2
)
(or heavier)
12 VDC
26811102
10.0
RED (positive +)
BLACK (negative -)
#14 AWG (2.5mm
2
)
(or heavier)
12 VDC
26815151
26815152
15.0
RED (positive +)
BLACK (negative -)
#14 AWG (2.5mm
2
)
(or heavier)