Product Manual
Assembly
17
10. To disconnect
permanently
When it is necessary to disconnect the remote switch power cord from the
battery, use the following procedure:
1. Disconnect the remote switch power cord from the solenoid valve power cord.
2. Disconnect the remote switch power cord from the vehicle battery as follows:
a) Disconnect vehicle battery ground wire.
b) Disconnect the battery cord’s black battery clamp or black wire
connector from the negative(-) terminal of the vehicle battery.
c) Disconnect the battery cord’s red battery clamp or red wire connector
from the positive(+) terminal of the vehicle battery.
d) Reconnect the vehicle battery ground wire.
WARNING: Always connect in this sequence to avoid possible shock.
Step Thirteen: Check and test completed assembly
WARNING
Check and test completed assembly
Serious injury could result from chemical leaks if broadcast kit is improperly
assembled or the design of the broadcast kit is modified.
Follow the steps below to ensure the broadcast kit is properly assembled.
Never modify the broadcast kit design.
1. Check assembly
Check assembly to assure the broadcast kit is properly assembled and in safe
working condition:
a) Check that all fittings and fasteners are tight, hose clamps are secure, and
electrical connections are properly attached.
b) While it is unlikely that factory assembled components become loose, they
should also be checked to make sure they are tight.
2. Test with water
Test the system for leaks with water:
a) Partially fill the tank with water.
b) Close the broadcast kit ball valve. (See operation instructions.)
c) Connect the remote switch to a 12V power source. (See assembly
instructions.) Make sure remote switch is in OFF position.
d) Start the sprayer. (See sprayer operation instructions.)
e) Ensure pressure is less than 75psi. (See sprayer operation instructions.)
f) Open the broadcast kit ball valve. (See operation instructions.)
g) Open the valve levers on the Y-valve.
h) Turn the remote switch on.
i) Check for leaks throughout the system. If a leak is detected, fix the leak
and re-test the system with water.