Product Manual
Operation (cont’d)
32
Exercise generator
every 4 weeks
The generator should be exercised regularly.
At least every four weeks, start the engine and let it run for 10 to 15 minutes
with a small load plugged in, such as a lamp or fan.
Monthly exercising of the generator will:
o Dry out any moisture that has accumulated in the windings. If left,
this moisture can cause corrosion in the winding.
o Ensure that the unit is operating properly should it be needed in an
emergency.
Perform regular
maintenance
Perform periodic maintenance as directed in this manual to keep the
generator in safe working condition.
Prepare engine for
long term storage if
needed
If you will not be able to exercise the generator regularly, you must
prepare the engine for long term storage to prevent gum deposits from
forming and causing malfunction of the engine.
Prepare engine for long term storage by following instructions in your
engine’s manual or using the following procedure:
o Removing all fuel from the tank and carburetor
OR
o Adding fuel stabilizer to the fuel (following manufacturer’s
instructions)
Fuel stabilizer steps:
1. Ensure fuel tank is full.
2. Add fuel stabilizer to fuel tank.
3. Run engine at least 10 minutes after adding stabilizer to
allow it to enter the fuel system.
4. Shut off engine
5. Disconnect spark plug wire and remove spark plug
6. Add one teaspoon oil through spark plug hole
7. Place rag over spark plug hole and turn starter (or pull the
recoil) a few times to lubricate the combustion chamber.
8. Replace spark plug, but do not reconnect the spark plug wire.