Product Manual

Installation
8
Step One: Mounting
This NorthStar pump is self-priming.
The pump should be located in an area that is dry and provides adequate ventilation.
The pump may be mounted in any horizontal position. DO NOT mount pump vertically, doing so
will prevent the Motor Armor system from operating correctly.
Secure the rubber base with #10 fasteners. DO NOT compress the base, as doing so will reduce
the ability to isolate vibration and noise. Note: Fasteners are not included.
Step Two: Plumbing
See table below for port size and recommended hose sizes.
o Remove shipping plugs from pump ports.
o Use NorthStar quick connect fittings to connect flexible high-pressure tubing to the quick
connect ported pumps.
o To insert quick connect fittings, lubricate O-ring with water and twist fitting while inserting
into pump port.
Pump model
Ports
Minimum inlet hose size
Minimum outlet hose size
157145
3/4" Quick Connect
1/2" (13mm) Inside diameter
3/8" (9.5mm) Inside diameter
157147
3/4" Quick Connect
1/2" (13mm) Inside diameter
1/2" (13mm) Inside diameter
157153
3/4" Quick Connect
1/2" (13mm) Inside diameter
1/2" (13mm) Inside diameter
Tubing should be compatible with the spraying fluid. At least 18" [450mm] length is suggested to
minimize stress on the fitting/ports and reduce noise. Allow for the shortest possible tubing route
and avoid sharp bends that may kink over time.
Installation of a 50-mesh strainer is recommended to prevent foreign debris from entering the
system. Failures due to foreign debris are not covered under the warranty.
NOTE: Restrictions on the inlet may cause a loss in performance. Inlet pressure must not exceed 30 psi [2.1
bar]
If a check valve is installed in the plumbing, it must have a cracking pressure of no more than 2
psi [.14 bar].
CAUTION
DO NOT locate the motor near low temperature plastics or combustible material. The surface
temperature of the motor may exceed 250°F [121°C].
Correct orientation