3. Connect pump
to battery
Connect the pump to a 12V DC battery using the following procedure:
a) Disconnect the vehicle battery ground wire.
b) Connect the pump’s red wire to the positive (+) terminal of the battery.
c) Connect the pump’s black wire to the negative (-) terminal of the
battery.
d) Reconnect the vehicle battery ground wire.
Note: Skip steps (a) and (d) if battery is not in a vehicle.
WARNING: Always connect in this sequence to avoid possible shock.
4. Disconnect
after use
AFTER EACH USE, disconnect power to the pump using the following
procedure:
a) Disconnect the vehicle battery ground wire.
b) Disconnect the pump’s black wire from the negative (-) terminal of
the battery.
c) Disconnect the pump’s red wire from the positive (+) terminal of the
battery.
d) Reconnect the vehicle battery ground wire.
Note: Skip steps (a) and (d) if battery is not in a vehicle.
WARNING: Always disconnect in this sequence to avoid possible shock.
NOTE: It is important to disconnect power to the pump when not in use for
safety reasons. ALWAYS verify that the power has been disconnected before
adding chemicals or servicing.
Note: A remote switch is recommended for temporarily shutting off the pump’s operation.