Product Manual

Steps for setting the cut-out & internal bypass pressure on 11.4
lpm and 18 lpm RV pumps.
1. Connect the plumbing ports to a water tank.
2. A ball valve and pressure gauge are required in the outlet plumbing line.
3. Turn pump on.
4. To set the internal bypass pressure at 60psi:
5. To set the cut-out pressure at 55psi:
Slowly close outlet ball valve until completely shut.
If pump turns off, rotate cut-out pressure adjustment screw clockwise until pump is running
continuously.
With continuously running pump, adjust internal bypass adjustment screw (clockwise to
increase pressure, counterclockwise to decrease pressure) until pressure on gauge is 60psi.
If the pump starts to cycle on/off while increasing internal bypass pressure, repeat step 4.a.i
before continuing to adjust the internal bypass screw.
Once the pump is running continuously at 60psi, continue to step 5.
Slightly open the outlet ball valve and adjust it until
the pump is operating at 55psi.
Slowly rotate the cut-out pressure adjustment
screw counterclockwise until the switch first
activates and turns the pump off. The pump
pressure switch may cycle rapidly depending on
outlet conditions.
To confirm the pressure switch setting: open the
outlet ball valve, then slowly close it to increase
pressure. The pump should start to cycle on/
off as the pressure approaches 55psi, then turn
completely off when the outlet valve is closed.
Cut-out pressure
adjustment screw
Internal Bypass
adjustment screw