Datasheet

Technical Bulletin
Nortel Business Communications Manager 200 and
Business Communications Manager 400
Technical Specifications
Base unit
Physical dimensions BCM400 BCM200
Depth 18.3 in.; 46.5 cm 18.3 in.; 46.5 cm
Width 17.5 in.; 44.5 cm 17.5 in.; 44.5 cm
Height 7.1 in.; 18.0 cm 3.5 in.; 9.0 cm
Weight Std. 35.2 lbs; Std. 24.9 lbs;
15.9 Kg 11.3 Kg
Redundant 46.7 lbs;
21.2 Kg
Components BCM400 BCM200
Media Bay Module Bays Four Two
CPU Processor Intel Celeron 1.2 GHz Intel Celeron 1.2 GHz
Memory (RAM) 256 MB SDRAM 256 MB SDRAM
Hard Drive 20 GB EIDE 20 GB EIDE
System Status LEDs
Power status, Hard drive activity, System status, PCI device monitoring
(MSC, WAN, NIC 1, NIC 2), Chassis/CPU temperature, Fan activity
reset button
The System Status Monitor Card controls and monitors fans, power
supply, chassis temperature and OS status.
Mounting options
Rack-mount (standard 19-inch rack); Stand-alone (feet included); Wall-
mount (optional wall-mount bracket available separately)
Power supply specifications
Standard power supply Redundant power supply (BCM400 only)
Auto-sensing Auto-sensing
300 Watts 350 Watts
90/264 VAC 90/264 VAC
6.0 A/3.0 A 7.0 A/3.5 A
60/50 Hz 60/50 Hz
Environmental specifications
Operating temperature 32º to 104ºF; 0º to 40ºC
Operating humidity 10% to 90% relative humidity,
non-condensing
Storage temperature -67º to 158ºF; -55º to 70ºC
Storage humidity Up to 95% relative humidity
Mechanical requirements
NEBS (GR-63-CORE) compliant for Transportation and Operational
Vibration per IEC 68-2-27, Package Drop Shock resistance per ISTA 1A
Transportation Bounce to IEC 68-2-55 and Unpackaged Drop to ISTA
Project 1A
Regulatory compliance
Electromagnetic emissions
Radiated Air Australia AS3548 Class A
North America CISPR22 Class A
United Kingdom EN55022 Class A
Conducted Power Leads Australia AS3548 Class A
North America CISPR22 Class A
United Kingdom EN55022 Class A
Immunity (Narrow band RF interference)
Radiated North America customer driven
(based on EN 61000-4-3)
United Kingdom/International
EN55024 : 1998
Conducted North America customer driven
(Based on EN 61000-4-6)
United Kingdom/International
EN55024 : 1998
Immunity to electrostatic discharge
Indirect No functional impairment up to +/- 8 kV
Direct Mated I/O ports and connectors,
No damage up to +/- 4 kV
Mated connector and cords,
No functional impairment up to +/- 8 kV,
No damage up to +/- 15 kV

Summary of content (4 pages)