Media Bay Module Installation Guide and Configuration Gui

Configuring DIP switch settings and definitions 93
R2MFC Media Bay Module Installation and Configuration Guide
Country code defaults
This section contains the default configuration associated to the country code set by the DIP
switches on the faceplate of the R2MFC MBM.
Mexico Config 1
E1 physical characteristics
Connector type: BNC
Line coding: HDB3
E1 framing
Frame mode: Alternate
Register signaling
Regret option: OFF
End of dialing (Incoming): terminated by indication from destination switch, or by MFC
forward signal FW_EndDigits
End of dialing (Outgoing): terminated by indication from destination switch, or by MFC
forward signal FW_EndDigits
R2 line signaling
Mexico Config 1 R2 signals are according to CCITT standard. See Table 28 for the Mexico Config
1 R2 signal definitions.
Note: CD bits are not used. They are set to 01 in transmit direction, and are ignored in receive direction.
Table 28 Mexico Config 1 R2 A/B signals
Forward Backward
SignalABSignalAB
Idle 1 0 Idle 1 0
Seize 0 0 Seize acknowledge 1 1
Clear forward 1 0 Answer 0 1
Clear back 1 1
Block 1 1