Media Bay Module Installation Guide and Configuration Gui

Chapter 5 Configuring the R2MFC MBM 53
R2MFC Media Bay Module Installation and Configuration Guide
3 Select the appropriate Bus # under Configuration > Resources > Telephony Resources in
the navigation tree.
The Bus # information frame displays. See Figure 19 for an example of the screen layout for
an R2MFC MBM configured on Bus 2.0.
Figure 19 BCM Bus configuration for R2MFC MBM
4 Configure the fields in the Details for Module: 2.0 panel. See Table 7 for parameters and
settings.
Table 7 Module configuration parameters
Parameter Setting
Trunk type PRI
Protocol Euro
Clock source Primary external (if only one
trunk module in system;
otherwise, it depends on the
synchronization scheme of
the BCM)
Overlap receiving Selected (On)
Local number length According to BCM local
dialing plan (customer -
dependent)
Note: This field appears
only when the Overlap
receiving field is selected.
E1 Parameters - CRC4 Not Selected (Off)