Media Bay Module Installation Guide and Configuration Gui

100 Configuring DIP switch settings and definitions
NN40010-300
Brazil Config 2
E1 physical characteristics
Connector type: BNC
Line coding: HDB3
E1 framing
Frame mode: Alternate
Register signaling
Regret option: OFF
End of dialing (Incoming): terminated by indication from destination switch, or by MFC
forward signal FW_EndDigits
End of dialing (Outgoing): terminated by indication from destination switch, or by MFC
forward signal FW_EndDigits
BW_OutOfOrder B_4 FW_Digit_13 I_13 FW_Categ_15 II_15
BW_ChangOrder B_4 FW_Digit_14 I_14 FW_KD_Local II_3
FW_ReqFault I_12 FW_Digit_15 I_15 FW_KD_LnDst II_2
FW_EndDigits I_15 FW_Categ_1 II_1
Table 36 Interpretation of transmitted MFC signals (Sheet 2 of 2)
Meaning Signal Meaning Signal Meaning Signal