User's Manual

34 Configuration management
NN10035-111 Standard MCP 1.1 FP1 (02.02) April 2003 Copyright © 2003, Nortel Networks
Nortel Networks Confidential
Discovery Probe
Time Period
Type: String
Range: 0-3600000
Default: 60000
Controls the frequency (in
milliseconds) of registration
messages (RSIPs) sent from the
RTP Media Portal to the SIP
Application Module in the absence
of MGCP+ messaging from the SIP
Application Module.
Host Receive Port Type: String
Range: 1025-65535
Default: 3904
Port on which the RTP Media Portal
listens for MGCP+ messaging from
the SIP Application Module.
Note: The use of the default value
for this property is highly
recommended.
Polltimer Delay Type: String
Range: 0-65535
Default: 20000
milliseconds
Time span (in milliseconds) required
for startup and initialization of the
cards. The host CPU waits this
period of time before attempting to
contact the cards. (This is how long
the host waits to talk to the cards to
ask if they are up yet.)
Note: The use of the default value
for this property is highly
recommended.
Polltimer Interval Type: String
Range: 0-65535
Default: 65000
milliseconds
Interval (in milliseconds) at which
the host polls the blades to ensure
they are still available. (Intermediate
checks just to make sure the blade
is still up.)
Note: The use of the default value
for this property is highly
recommended.
Minor Port Usage
Alarm Level
Type: Percent
Range: 0-100
Default: 50
The percent usage at which the
number of ports used on the public
or private side of an RTP Media
Portal (over all blades) causes a
minor alarm.
Table 2 RTP Media Portal tab configurable properties