Computer Accessories User Manual
22 Configuring an MPANL tunneled through public frame relay
241-6401-280 6.0S1
PROV> end prov
Verifying the MPANL connection
Once the provisioning is complete on both the 4400 and 6400, verify the link.
On the 4400
CLI> show msm linkstatus table
IfIndex : 149
InterfaceType : dte
LAPFStatus : up
LocalComponentName : "MPA_1 MPANL/149"
RemoteComponentName: "PPNODE mpanl/5117 SigMpanl"
RemoteGenCfgType : nortelAccessDevice
PANLStatus : up
When the MPANL is up, the local and remote node names are displayed.
The LAPF and PANL status display as up.
Note:
If using a 2.0 release, use the command:
CLI> show msm dtelinkstatus table
IfIndex : 155
LAPFStatus : up
LocalComponentName : "MPA_1 MPANL/155"
RemoteComponentName: "PPNODE mpanl/5117 SigMpanl"
On the 6400
> d lp/5 v35/1
Unlocked and enabled.
> d frmux/51
Unlocked and enabled.
> d frmux/51 lmi
Unlocked and enabled;
protocolStatus - normalCondition.
> d frmux/51 framer
Unlocked and enabled;
no errors displayed;
frames being sent to/from the interface.