Part No.
Copyright © 2001 Nortel Networks All rights reserved. August 2001. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Networks Inc.
USA requirements only Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy.
Japan/Nippon requirements only Voluntary Control Council for Interference (VCCI) statement (Class A) Voluntary Control Council for Interference (VCCI) statement (Class B Contivity 1600 and 2600) Taiwan requirements Bureau of Standards, Metrology and Inspection (BSMI) statement Canada requirements only Canadian Department of Communications Radio Interference Regulations This digital apparatus (Contivity VPN Switch) does not exceed the Class A limits for radio-noise emissions from digital apparatus as s
Canadian Department of Communications Radio Interference Regulations This digital apparatus (Contivity 1600 and Contivity 2600) does not exceed the Class B limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
Pour sa propre protection, l'utilisateur doit s'assurer que tous les fils de mise à la terre de la source d'énergie électrique, des lignes téléphoniques et des canalisations d'eau métalliques, s'il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales. Avertissement: L'utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir recours à un service d'inspection des installations électriques, ou à un électricien, selon le cas.
2. Your telephone company may make changes to its facilities, equipment, operations, or procedures that could affect the proper functioning of your equipment. The telephone company will notify you in advance of such changes to give you an opportunity to maintain uninterrupted telephone service. 3. If the unit causes harm to the telephone network, the telephone company may temporarily discontinue your service.
remedy Nortel Networks will at its discretion provide a suitable fix, patch, or workaround for the problem that may be included in a future Software release. Nortel Networks further warrants to Licensee that the media on which the Software is provided will be free from defects in materials and workmanship under normal use for a period of 90 days from the date Software is first shipped to Licensee.
Contents Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Related publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Text conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing Contivity 2500/2000/4000 LAN/WAN option cards . . . . . . . . . . . . . . . . . . . . 48 Installing Contivity 2500/2000/4000 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Replacing a Contivity 4000 power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Replacing a Contivity 4000 disk drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Installing Contivity 2500/2000/4000 DIMMs . . . . . . . . . . . . . . .
Figures Figure 1 Removing the Contivity 4600 front bezel . . . . . . . . . . . . . . . . . . . . . . . . . 20 Figure 2 Contivity 4600 front components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Figure 3 Sample Contivity 4600 system board . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 4 Installing Contivity 4600 LAN/WAN and hardware accelerator cards . . . . 23 Figure 5 Installing Contivity 4600 DIMMs . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 30 Removing the Contivity 1600 power cord . . . . . . . . . . . . . . . . . . . . . . . . . 69 Figure 31 Removing the Contivity 1600 top cover . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Figure 32 Contivity 1600 system board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Figure 33 Removing the Contivity 1600 power cord . . . . . . . . . . . . . . . . . . . . . . . . . 72 Figure 34 Installing Contivity 1600 LAN/WAN option cards . . . . . . . . . . . . . .
Preface This document describes how Nortel Networks* trained service personnel can install or replace hardware components for models 4600, 4500, 4000, 2600, 2500, 2000, 1600, and 600 of the Contivity* products.
Preface This guide refers to the Contivity 4600, 4500, 4000, 2600, 2000, 1600, and 600 as the switch. It assumes that you are familiar with Web browsers and their general operation. Related publications The following list shows the associated documentation that you will need to configure and manage the switch. • • • Contivity VPN Switch Release Notes provide the latest information, including known problems, workarounds, and special considerations.
Preface 15 braces ({}) Indicate required elements in syntax descriptions where there is more than one option. You must choose only one of the options. Do not type the braces when entering the command. Example: If the command syntax is show ip {alerts|routes}, you must enter either show ip alerts or show ip routes, but not both. brackets ([ ]) Indicate optional elements in syntax descriptions. Do not type the brackets when entering the command.
Preface vertical line ( | ) Separates choices for command keywords and arguments. Enter only one of the choices. Do not type the vertical line when entering the command. Example: If the command syntax is show ip {alerts|routes}, you enter either show ip alerts or show ip routes, but not both. asterisk (*) Indicates a trademark. See the Title Page for trademark information.
Preface 17 URL Uniform Resource Locator VPN Virtual private network WAN Wide area network Hard-copy technical manuals You can print selected technical manuals and release notes free, directly from the Internet. Go to the www.nortelnetworks.com/documentation URL. Find the product for which you need documentation. Then locate the specific category and model or version for your hardware or software product.
Preface An Express Routing Code (ERC) is available for many Nortel Networks products and services. When you use an ERC, your call is routed to a technical support person who specializes in supporting that product or service. To locate an ERC for your product or service, go to the www12.nortelnetworks.com/ URL and click Express Call Routing at the bottom of the page.
Chapter 1 Contivity 4600 Option Installation This section describes how to install or replace hardware components for the Contivity 4600. Caution: Wear an antistatic band when handling electronic components for the switch to avoid damaging them. Warning: Turn off the switch and unplug both power cords before installing LAN and WAN cards or system memory.
Chapter 1 Contivity 4600 Option Installation Figure 1 shows you how to remove the front bezel from the Contivity 4600. You do not need to turn off the switch to remove the front bezel when installing a power supply or hard disk drive.
Chapter 1 Contivity 4600 Option Installation 21 Figure 2 shows the Contivity 4600 front components.
Chapter 1 Contivity 4600 Option Installation Contivity 4600 system board layout This section shows the Contivity 4600 system board. Warning: Only Nortel Networks trained service personnel should change existing hardware configurations. Improper handling of internal components or assemblies, with the power connected, could cause severe injury. Figure 3 shows a sample Contivity 4600 system board, including the Dual Inline Memory Modules (DIMMs) and peripheral component interconnect (PCI) slots.
Chapter 1 Contivity 4600 Option Installation 23 Installing Contivity 4600 LAN/WAN and hardware accelerator cards This section describes how you install option cards in the switch option card slide-out tray. The following procedure is for Nortel Networks trained service personnel only. 1 Turn off the switch and unplug both power cords from the power source. 2 Unscrew the four slotted thumb-screws securing the slide-out tray. Pull out the tray by gripping it with the screws. It will only pull out halfway.
Chapter 1 Contivity 4600 Option Installation 7 Plug in both power cords to the power source and turn on the switch. Caution: Be careful when inserting option cards into the Contivity 4600, because the slide-out tray is not fully supported once pulled out. You should support the back of the tray with your hand while inserting an option card. Installing Contivity 4600 DIMMs Figure 6 shows you how to unlock a DIMM in the Contivity 4600, and remove or install a DIMM.
Chapter 1 Contivity 4600 Option Installation 25 Figure 5 Installing Contivity 4600 DIMMs Alignment Keys 2 1 3 2 4 Locking lever CS460009A 7 Pull up the locking levers on both sides of the next available DIMM, and snap the DIMM into its socket. 8 Replace the support bracket by tightening the two secured captive screws and the rear Phillips screw. 9 Push in the slide-out tray and tighten the thumb-screws.
Chapter 1 Contivity 4600 Option Installation Figure 6 Removing a Contivity 4600 power supply Bo ot/ Ale Read rt/F y ail CS460010A 3 Grab the handle and pull the power supply firmly, until the device disengages. Be careful of the sharp sheet-metal edges. 4 Insert the new power supply. Make sure it seats firmly in its socket and is locked in. Be sure the green power LED on the front of the power supply is on. 5 Secure the power supply screws tightly with a screwdriver. 6 Replace the front bezel.
Chapter 1 Contivity 4600 Option Installation 27 Replacing a Contivity 4600 hard disk drive Figure 7 shows you how to replace Contivity 4600 hard disk drives for the switch. Caution: Hard disks are not hot-swappable. To replace a hard disk drive, you must do the following: Software First save any data that has not yet been saved to the hard disk from the disk cache: 1 Use your Web browser to navigate to the switch, and go to the Admin!File System display.
Chapter 1 Contivity 4600 Option Installation Figure 7 Removing a Contivity 4600 hard disk drive Bo ot/ Ale Read rt/F y ail Drive 0 Drive 1 Insert and turn key, then remove hard disk by handle. CS460011A 3 Insert the replacement hard drive fully, and lock it by turning the key clockwise. Make sure the hard disk drive LED shows the proper drive number. 4 Replace the front bezel.
Chapter 1 Contivity 4600 Option Installation 29 Software Enable the switch by following these steps: 1 Use your Web browser to navigate to the switch, and go to the Admin!File System display. 2 Click on the drive and click the Enable button.
Chapter 1 Contivity 4600 Option Installation 302283-E Rev 00
Chapter 2 Contivity 4500 Option Installation This section describes how to install or replace hardware components for the Contivity 4500. Warning: Wear an antistatic band when handling electronic components for the Contivity switch to avoid damaging them. Note: Turn off the Contivity switch and unplug it before installing LAN or WAN cards, or system memory.
Chapter 2 Contivity 4500 Option Installation 1 Insert a flat-head screwdriver into the slots on the lower left and right sides of the chassis, and pry the bezel forward. 2 Slide your fingers between the front bezel and the switch. 3 Pull the bezel forward firmly, separating the ball studs on the bezel from the sockets on the chassis. Figure 8 shows you how to remove the front bezel from the switch. You do not need to turn off the switch to remove the front bezel.
Chapter 2 Contivity 4500 Option Installation 33 Remove the Contivity 4500 front bezel to: • • • Replace a power supply. Replace a hard disk drive. Insert the recovery diskette. Figure 9 shows the Contivity 4500 front components. Figure 9 Contivity 4500 front components Disk drives 3.
Chapter 2 Contivity 4500 Option Installation Contivity 4500 system board layout This section describes installing option cards onto the system board. Warning: Only Nortel Networks trained service personnel should change existing hardware configurations. Improper handling of internal components or assemblies, with the power connected, could cause severe injury. Note: Wear an antistatic band when handling electronic components for the switch to avoid damaging them.
Chapter 2 Contivity 4500 Option Installation 35 Figure 10 shows the Contivity 4500 system board, in particular the DIMMs and option card slots.
Chapter 2 Contivity 4500 Option Installation Installing Contivity 4500 LAN/WAN and hardware accelerator option cards This section describes how you install option cards into the Contivity 4500 option card slide-out tray. The following procedure is for Nortel Networks trained service personnel only. 1 Turn off the switch and unplug both power cords from the power source. 2 Unscrew the four slotted thumb screws securing the slide-out tray. Pull out the tray by gripping it with the screws.
Chapter 2 Contivity 4500 Option Installation 37 Figure 11 shows you how to install LAN, WAN, or hardware accelerator option cards into the Contivity 4500. You can use the 6 slots for any mix of LAN and WAN or hardware accelerator cards; however, you must populate the slots from bottom to top, in that order.
Chapter 2 Contivity 4500 Option Installation Installing Contivity 4500 DIMMs Figure 12 shows you how to unlock a Dual Inline Memory Module (DIMM) in the Contivity 4500, and remove or install a DIMM. Install a DIMM in the next available slot (for example, if the DIMM #1 slot is populated, then add the next DIMM to the DIMM #2 slot).
Chapter 2 Contivity 4500 Option Installation 39 To install a DIMM into the Contivity 4500, follow these steps: 1 Turn off the switch. 2 Remove the power cords. 3 Unscrew the slide-out tray at the back of the unit and pull it out using the thumb screws. 4 Remove the support bracket by loosening the two secured captive screws and the rear Phillips screw. 5 Press down the locking levers on both sides of the next available DIMM slot to allow the new DIMM to be inserted.
Chapter 2 Contivity 4500 Option Installation Replacing a Contivity 4500 power supply Figure 13 shows you how to replace a hot-swappable power supply for the Contivity 4500. Figure 13 Removing a Contivity 4500 power supply Bo ot/ Ale Read rt/F y ail CS460010A To remove the power supply: 1 Remove the front bezel as shown in Figure 8. 2 Use a flat-head screwdriver to unscrew the top and bottom power supply screws. 3 Grab the handle and pull the power supply firmly, until the device disengages.
Chapter 2 Contivity 4500 Option Installation 41 4 Insert the new power supply. Make sure the power supply seats firmly in its socket and is locked in. Be sure the green power LED on the front of the power supply is on. 5 Secure the power supply screws tightly with a screwdriver. 6 Replace the front bezel. Replacing a Contivity 4500 hard disk drive Warning: Contivity 4500 hard disks are not hot-swappable.
Chapter 2 Contivity 4500 Option Installation Figure 14 Removing a Contivity 4500 hard disk drive Bo ot/ Ale Read rt/F y ail Drive 0 Drive 1 Insert and turn key, then remove hard disk by handle. CS460011A 3 Insert the replacement hard drive fully, and lock it by turning the key clockwise. Make sure the hard disk drive LED shows the proper drive number. 4 Replace the front bezel. 5 Reload the software on the disk.
Chapter 3 Contivity 2500/2000/4000 Option Installation This section describes how to install or replace hardware components for the Contivity 2500, 2000, and 4000. Warning: Wear an antistatic band when handling electronic components for the Contivity switch to avoid damaging them. Note: Turn off the Contivity switch and unplug it before installing LAN or WAN cards, or system memory.
Chapter 3 Contivity 2500/2000/4000 Option Installation Figure 15 Removing the Contivity 2500/2000/4000 front bezel Slide fingers behind front bezel and firm ly pull forward in the direction of arrows. Front Bezel The first few times you remove the front bezel it will be rather difficult to remove. This is because the ball stud and sockets are new. After a few times, removal is easier. Sliding the top cover back is optional; it allows you to get a better grip on the front bezel for removal.
Chapter 3 Contivity 2500/2000/4000 Option Installation 45 Removing the Contivity 2500/2000/4000 top cover Figure 16 shows you how to remove the top cover from the Contivity 2500/2000/ 4000. You must remove the cover to: • Install LAN, WAN, or hardware accelerator cards • Install additional memory Figure 16 Removing the Contivity 2500/2000/4000 top cover To remove the Contivity 2500/2000/4000 top cover: 1 Turn off the switch's power and unplug it.
Chapter 3 Contivity 2500/2000/4000 Option Installation Contivity 2500/2000/4000 system board layout Figure 17 shows the Contivity 2500/200 system board, in particular the DIMMs, option card slots, and the CPU cooling fan. The Contivity 4000 system board is similar, but has two CPUs as shown in Figure 18.
Chapter 3 Contivity 2500/2000/4000 Option Installation 47 Figure 18 Sample Contivity 4000 system board Installing Hardware Options for the Contivity VPN Switch
Chapter 3 Contivity 2500/2000/4000 Option Installation Installing Contivity 2500/2000/4000 LAN/WAN option cards Figure 19 shows you how to install LAN or WAN option cards into a Contivity 2500/2000/4000. You can use Slots 1 to 3 for any mix of LAN and WAN cards. Note that Slot 4 is not supported.
Chapter 3 Contivity 2500/2000/4000 Option Installation 49 To install an option card: 1 Turn off the switch and remove the power cord. 2 Remove the front bezel and top cover as shown in Figure 16. 3 Remove the filler panel screw and pull out the filler panel as shown in Figure 19. 4 Slide the option card into the intended slot. Make sure the card seats firmly and evenly in the card slot. If the card is not seated properly, it will not work. 5 Replace the card and screw.
Chapter 3 Contivity 2500/2000/4000 Option Installation Figure 20 Installing Contivity 2500/2000/4000 DIMMs Alignment keys To remove DIMMs, pull back locking lever and pull out DIMM. To install DIMMs, pull back locking levers and push in DIMM Locking lever CS260019A Replacing a Contivity 4000 power supply Figure 21 shows you how to replace a power supply for a Contivity 4000.
Chapter 3 Contivity 2500/2000/4000 Option Installation 51 Figure 21 Removing a Contivity 4000 power supply P re s s d o w n o n th e re le a s e b u tto n a n d re m o ve p o w e r su p p ly b y p u llin g h a n d le . To remove a Contivity 4000 power supply, remove the switch’s front bezel, then follow these steps: 1 Press the button down to turn off the power supply. 2 Press down on the release button. 3 Pull the handle forward. 4 Insert the new power supply.
Chapter 3 Contivity 2500/2000/4000 Option Installation Replacing a Contivity 4000 disk drive To replace a Contivity 4000 disk drive, you must do the following: Software First save any data that has not yet been saved to the hard disk from the disk cache: 1 Use your Web browser to navigate to the switch, and go to the Admin!File System display. 2 Click the button “Prepare selected device for removal.
Chapter 3 Contivity 2500/2000/4000 Option Installation 53 Figure 22 Removing a Contivity 4000 hard disk drive D rive 0 D rive 1 In sert an d tu rn ke y, th en re m ove ha rd disk by h an dle. 2 Pull the handle to remove the hard disk drive. 3 Insert the replacement hard drive fully, and lock it by turning the key clockwise. Make sure the hard disk drive LED shows the proper drive number. 4 Replace the front bezel. 5 Reload the software on the disk.
Chapter 3 Contivity 2500/2000/4000 Option Installation Software Enable the switch by following these steps: 1 Use your Web browser to navigate to the switch, and go to the Admin!File System display. 2 Click on the drive and click the Enable button.
Chapter 3 Contivity 2500/2000/4000 Option Installation 55 To replace or change a DIMM, follow these steps. 1 Turn off the switch. 2 Remove the power cord. 3 Remove the front bezel as shown in Figure 15. 4 Remove the top cover as shown in Figure 16. 5 Press down the locking levers on both sides of the next available slot to allow the new DIMM to be inserted. 6 Pull the DIMM up to remove it from the slot. 7 Place a new DIMM in the slot, making sure to properly position the DIMM's alignment keys.
Chapter 3 Contivity 2500/2000/4000 Option Installation 302283-E Rev 00
Chapter 4 Contivity 2600 Option Installation This section describes how to install or replace hardware components for the Contivity 2600. Warning: Wear an antistatic band when handling electronic components for the Contivity switch to avoid damaging them. Note: Turn off the Contivity switch and unplug it before installing LAN or WAN cards, or system memory. Opening the Contivity 2600 To access the Contivity 2600 disk drive for system recovery operations, you must first remove the switch’s front bezel.
Chapter 4 Contivity 2600 Option Installation Removing the Contivity 2600 front bezel Note: Removing the front bezel on the Contivity 2600 system activates the chassis intrusion alarm whether or not the switch is turned on. This intrusion is reported to the system log file. You must remove the bezel to insert the recovery diskette. Note that you do not need to turn off the switch if you are only removing the front bezel. Figure 24 shows you how to remove the front bezel from the switch.
Chapter 4 Contivity 2600 Option Installation 59 The first few times you remove the front bezel it will be rather difficult to remove. This is because the ball studs and socket clips are new. After a few times, removal is easier. To remove the front bezel, you need a Phillips screwdriver. 1 Turn each of the two screws on the front bezel a quarter turn counter-clockwise. 2 Grip the two handles and pull the bezel towards you firmly to unsnap it from the chassis.
Chapter 4 Contivity 2600 Option Installation Figure 25 Removing the Contivity 2600 top cover Remove these four screws Boot/Ready Boot/Ready Alert/Fail Boot/Ready Slide cover forward and lift up CS260006A ➨ Slide the top cover forward approximately 1/4 inch, then lift the lid 2 to 3 inches and move it away from the chassis. Contivity 2600 system board layout Figure 26 shows the Contivity 2600’s system board, in particular the DIMMs, option card slots, and the CPU cooling fan.
Chapter 4 Contivity 2600 Option Installation 61 Figure 26 The Contivity 2600 system board DIMMs 1 2 CPU cooling fan 4 Option card slots 1 2 3 4 CS260008A Warning: Beware of danger if battery is incorrectly replaced. Replace with the same or an equivalent battery only, as recommended by the manufacturer’s instructions. Danger: In spite of the above warning, which is mandated for regulatory approval, you should not change the battery.
Chapter 4 Contivity 2600 Option Installation Installing LAN/WAN and hardware accelerator option cards Figure 27 shows you how to install LAN, WAN, or hardware accelerator option cards into the switch. You can use Slots 1 to 4 for any mix of LAN and WAN cards. Figure 27 Installing LAN/WAN or hardware accelerator cards Rear of Unit Filler Panel Option Card Motherboard Option Card Slots CS2600017A To remove the front bezel and cover, you need a Phillips screwdriver. 1 Power off the switch.
Chapter 4 Contivity 2600 Option Installation 63 3 Remove the front bezel as shown in Figure 24. 4 Remove the top cover as shown in Figure 25. 5 Remove the filler panel screw and pull out the filler panel as shown in Figure 27. Caution: Be careful when inserting option cards into the Contivity 2600, as the slide-out tray is not fully supported once pulled out. You should support the back of the tray with your hand while inserting an option card. 6 Slide the option card into the intended slot.
Chapter 4 Contivity 2600 Option Installation Installing Contivity 2600 DIMMs Figure 28 shows you how to unlock a Dual Inline Memory Module (DIMM) and remove or install the DIMM in the next available slot (for example, if the DIMM #1 slot is populated, add the next DIMM to the DIMM #2 slot). Figure 28 Installing Contivity 2600 DIMMs Alignment keys To remove DIMMs, pull back locking lever and pull out DIMM.
Chapter 4 Contivity 2600 Option Installation 65 To replace or change a DIMM, follow these steps. 1 Turn off the switch. 2 Remove the power cord. 3 Remove the front bezel as shown in Figure 24. 4 Remove the top cover as shown in Figure 25. 5 Press down the locking levers on both sides of the next available slot to allow the new DIMM to be inserted. 6 Pull the DIMM up to remove it from the slot. 7 Place a new DIMM in the slot, making sure to properly position the DIMM's alignment keys.
Chapter 4 Contivity 2600 Option Installation 302283-E Rev 00
Chapter 5 Contivity 1600 Option Installation This chapter describes how Nortel Networks trained service personnel can change existing hardware configurations, including installing LAN and WAN cards and how to add memory for the Contivity 1600. Warning: Wear an antistatic band when handling electronic components for the Contivity switch to avoid damaging them. Note: Turn off the Contivity switch and unplug it before installing LAN or WAN cards, or system memory.
Chapter 5 Contivity 1600 Option Installation Removing the Contivity 1600 front bezel You must remove the bezel to insert the recovery diskette. Note that you do not need to turn off the Contivity switch if you are only removing the front bezel. Figure 29 shows you how to remove the front bezel from the Contivity switch. Warning: When handling the Contivity switch outside of the rack-mount shelf, do not use the part labeled with the Nortel Networks logo and the LEDs as a handle.
Chapter 5 Contivity 1600 Option Installation 69 Removing the Contivity 1600 top cover To install LAN or WAN cards, or to install additional memory, you must remove the Contivity 1600’s front bezel and then the switch’s top cover. To remove the cover you need a Phillips screwdriver. Note: You do need to turn off the Contivity switch to remove the top cover. 1 Turn off the switch’s power and remove the power cord. Figure 30 shows how to remove the power cord from the Contivity switch.
Chapter 5 Contivity 1600 Option Installation 4 Use the Phillips screwdriver to remove the four screws that secure the cover to the chassis, as shown in Figure 31. Figure 31 Removing the Contivity 1600 top cover Remove these four screws Alert/Firm Boot/Ready Alert/Fail Boot/Ready Slide cover forward and lift up CS160003A 5 302283-E Rev 00 Slide the top cover forward approximately 1/4 inch, then lift the lid 2 to 3 inches, and move it away from the chassis.
Chapter 5 Contivity 1600 Option Installation 71 Contivity 1600 system board layout Figure 32 shows the Contivity 1600’s system board, in particular the DIMMs, option card slots, and the CPU cooling fan. Figure 32 Contivity 1600 system board Option card slots (only two are usable) DIMMs (1 and 2) 2 1 DIMM slots Not used 1 2 PCI slots CS160004A Warning: Beware of danger if the battery is incorrectly replaced.
Chapter 5 Contivity 1600 Option Installation Installing Contivity 1600 option cards This section shows you how to install LAN or WAN option cards in the Contivity 1600. 1 Turn off the switch. 2 Remove the power cord, as shown in Figure 33. Figure 33 Removing the Contivity 1600 power cord 100-2240VAC 2-1A 50-60Hz Power cable CS160009A 3 302283-E Rev 00 Remove the front bezel, as shown in Figure 29.
Chapter 5 Contivity 1600 Option Installation 73 4 Remove the top cover, as shown in Figure 31. 5 Remove the filler panel screw and pull out the filler panel, as shown in Figure 34. Figure 34 Installing Contivity 1600 LAN/WAN option cards Screwdriver slots Phillips screw Option card slot Option card Motherboard CS160020A 6 Slide the option card into the intended slot, as shown in Figure 35. Make sure the card seats firmly and evenly into the card slot.
Chapter 5 Contivity 1600 Option Installation Figure 35 Installing Contivity 1600 option cards Option card Option card slot Motherboard CS160019A 7 Replace the card and screw. 8 Replace the top cover. 9 Replace the front bezel. 10 Reconnect the power cord. 11 Turn on the switch.
Chapter 5 Contivity 1600 Option Installation 75 Installing Contivity 1600 DIMMs Figure 36 shows you how to unlock a DIMM and remove or install the DIMM in the next available slot (for example, if the DIMM # 1 slot is populated, than add the next DIMM to the DIMM # 2 slot). Figure 36 Installing Contivity 1600 DIMMs Alignment keys To remove DIMMs, pull back locking levers and pull out DIMM. To install DIMMs, pull back locking levers and push in DIMM.
Chapter 5 Contivity 1600 Option Installation To replace a DIMM, follow these steps. 1 Turn off the switch. 2 Remove the power cord as shown in Figure 30. 3 Remove the front bezel as shown in Figure 29. 4 Remove the top cover as shown in Figure 31. 5 Press down the locking levers on both sides of the DIMM as shown in Figure 36. 6 Pull the DIMM up to remove it from the slot. 7 Place a new DIMM in the slot, making sure to properly position the DIMM's alignment keys.
Chapter 6 Contivity 600 Option Installation This chapter describes how Nortel Networks trained service personnel can change existing hardware configurations, including installing LAN and WAN cards for the Contivity 600. Note: The expansion slot is renamed to Slot 2 by the Contivity 600 software. Warning: Wear an antistatic band when handling electronic components for the Contivity 600 to avoid damaging them.
Chapter 6 Contivity 600 Option Installation 9 Reconnect the power cord to turn the switch back on. Opening the Contivity 600 To access the system, you must remove remove all cables, the power cord, and the bottom metal screws and pull the chassis from the rear. You need a Phillips screwdriver to access the system. 1 Unplug the switch’s power cord from the back of the chassis and all the signal cables. 2 Turn the switch over to see the bottom of the box.
Chapter 6 Contivity 600 Option Installation 79 Figure 37 Removing the bottom screws 1 2 3 4 CS60003A 4 Firmly pull the chassis towards you to loosen it from the casing. You can gently shake it so that it slips outwards and into your hand or you can pull gently on the I/O expansion bay. Figure 38 shows how to remove the system from the chassis.
Chapter 6 Contivity 600 Option Installation Figure 38 Removing the system from the chassis I/O EXPA NSION CONSOL E BAY LAN 1 FD LAN 0 RC DC INPU +12V-1. T 7A -12V-0.1 A +5V-10 A 75W MA X CS60004A l Contivity 600 system board layout Figure 39 shows the Contivity 600 system board, in particular the option card slot, DIMM memory, and the CPU cooling fan.
Chapter 6 Contivity 600 Option Installation 81 Figure 39 Contivity 600 system board Option card slot CPU cooling fan DIMM slot CS60005A Warning: Beware of danger if the battery is incorrectly replaced. Replace with the same or an equivalent battery only, as recommended by the manufacturer’s instructions. Danger: In spite of the above warning, which is mandated for regulatory approval, you should not change the battery. If you suspect a dead battery, contact Nortel Networks Customer Support.
Chapter 6 Contivity 600 Option Installation 1 Remove the blank PCI bracket by inserting a Phillips screw driver into the slot at the right of the blank PCI bracket and rotating the screw counter-clockwise. 2 Lift out the blank PCI bracket, and slide the replacement card into the intended slot. Note: Be careful not to bend the copper fingers in the slot. Make sure the card seats firmly and evenly in the card slot and that the left tabbed-end of the card is seated in its slot.
Chapter 6 Contivity 600 Option Installation 83 Memory option The Contivity 600 ships with 64 Mbits of memory installed. No additional memory can be installed.
Chapter 6 Contivity 600 Option Installation 302283-E Rev 00
Index A M acronyms 16 memory size 55, 65, 76, 83 additional memory installing 45 antistatic 19, 34 O option cards slots 22, 35 C conventions 14 P conventions, text 14 customer support 17 power supplies 33 replacing a 40 D power supply replacing a 50 DIMMs 16, 22, 35 installing 24, 38, 49, 54, 64, 75 documentation map 14 product support 17 publications hard copy 17 DSU/CSU required 16 R F recovery diskette drive 33, 58, 68, 78 front bezel removing 19, 20, 31, 32, 43, 44, 58, 68 S H s