Server User Manual
426 Maintenance
If self-tests T:10-T:17 fail, the display contains the failure message for three
seconds and the ITG-Pentium 24-port trunk card goes on to the next test. If
more than one test fails, the message displayed indicates the last failure.
Table 70
ITG-Pentium 24-port trunk card faceplate maintenance display message
summary
Normal
Code
Fault
Code Description
T:00 F:00 Initialization
T:01 F:01 Testing Internal RAM
T:02 F:02 Testing ALU
T:03 F:03 Testing address modes
T:04 F:04 Testing Boot ROM
T:05 F:05 Testing timers
T:06 F:06 Testing watchdog
T:07 F:07 Testing external RAM
T:08 F:08 Testing Host DPRAM
T:09 F:09 Testing DS30 DPRAM
T:10 F:10 Testing for presence of security device. The
ITG-Pentium 24-port trunk card has no security device.
For the ITG-Pentium 24-port trunk card, a momentary
display of F:10 is normal.
T:11 F:11 Testing flash memory
T:12 F:12 Programming PCI FPGA
T:13 F:13 Programming DS30 FPGA
T:14 F:14 Programming CEMUX FPGA
T:15 F:15 Programming DSP FPGA
T:16 F:16 Testing CEMUX interface
T:17 F;17 Testing EEPROM
T:18 F:18 Booting host, waiting for response with self-test
information
PT:0 PF:0 Pentium module suspend signal OK
PT:1 PF:1 Pentium module powered OK
If the displays this message, check that the Pentium
module is fully seated in the motherboard socket.
T:19 Waiting for application startup message from host
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright © 2007, Nortel Networks
.