Server User Manual
204 Install and configure IP Trunk 3.01 (and later) node
Table 45
NTAK02 SDI/DCH switch settings for IP Trunk 3.01 (and later) DCHIP
Port 1
SW 1-1 SW 1-2
DCH OFF OFF
Port 3
SW 1-3 SW 1-4
DCH OFF OFF
Table 46
NTAK02 SDI/DCH jumper settings for the IP Trunk 3.01 (and later)
DCHIP
Port
Jumper
location
Strap for
DTE
Jumper
location RS422
J7 C – B J9 C – BPort 1
J6 C – B J8 C – B
J4 C – B J2 C – BPort 3
J3 C – B J1 C – B
2
Connect the NTAK19FB Quad Serial I/O SDI/DCH Cable (or
equivalent) to the I/O connector for the card slot in which the
SDI/DCH card is installed.
3
If the DCHIP card is installed in the main cabinet with the SDI/DCH
card, then use NTWE04AD SDI/DCH Extension Cable (1 ft) from the
NTCW84KA DCH (P5) connector to the NTAK19FB D-Channel port
connector for Port 1 or Port 3.
4
If the DCHIP card is installed in the expansion cabinet, then use
NTWE04AC SDI/DCH Extension Cable (10 ft) from the NTCW84KA
DCH (P5) connector to the NTAK19FB D-Channel port connector
for Port 1 or Port 3.
—End—
Install the serial cable
Follow the steps in Procedure 14 "Installing the serial cable" (page 205) to
install the serial cable.
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007
Copyright © 2007, Nortel Networks
.