194 Install and configure IP Trunk 3.01 (and later) node
Remove existing I/O panel filter adapter
The standard I/O filter adapter is shielded metal with a black plastic insert
connector. The NTCW84JA adapter uses yellow warning labels to indicate
EMC filtering modifications and which MDF connection points can support
100BaseT connection.
Follow the steps in Procedure 8 "Removing the existing I/O panel filter
adapter" (page 194) to remove the existing I/O panel filter adapter.
Procedure 8
Removing the existing I/O panel filter adapter
Step Action
1
Remove the ITG pack, or any other IPE pack, from the IPE shelf
card slot corresponding to the I/O Panel connector to be removed.
Make sure to use the I/O panel connector which corresponds to the
left slot number of the DCHIP card.
2
Remove the NT8D81AA Backplane to I/O Panel r ibbon cable
assembly which is connected to the backplane side of the existing
block by releasing the latching pins on the filter block and pulling the
NT8D81AA cable away.
3
Unscrew the existing filter adapter from the I/O panel. There is one
screw on the lower front of the adapter and one screw on the upper
back of the adapter. Remove the adapter.
4
Re-position the new NTCW84JA filter adapter in the now vacant I/O
panel opening. (See Figure 35 "NTCW84JA 50 pin I/O Panel Filter
Connector Block" (page 195).)
5
Attach the new NTCW84JA to the I/O panel by securely fastening
the top back screw and the bottom front screw.
6
Reconnect the NT8D81AA cable and secure it in place by snapping
shut the locking latches provided on the NTCW84JA connector.
—End—
Nortel Communication Server 1000
IP Trunk Fundamentals
NN43001-563 02.01 Standard
Release 5.5 21 December 2007