Network Card User's Manual

Installation procedures 77
The power source must not feed the power back into the DSL
through the RJ-45 wall outlet, only to the local ISDN BRI terminal.
The power adapter is normally supplied with the terminal.
Figure 28 "Connecting the ISDN BRI terminal to the S/T interface"
(page 78) illustrates an ISDN BRI terminal connection to an S/T
interface. Figure 29 "Connecting the ISDN network terminator to the
U interface" (page 79) illustrates an ISDN BRI terminal connection to
a U interface.
3
Enter the Static TEI at the terminal.
Note: Do not perform this step to assign Dynamic TEIs since
they are automatically assigned.
4 Enter the Service Profile ID number at the terminal.
For detailed information about this procedure, refer to the terminal
user guide.
5
Repeat step 1 to step 4 for each ISDN BRI terminal.
—End—
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning