Network Card User's Manual
Installing ISDN BRI hardware for line applications 23
8
Repeat steps 1 through 7 for each card requiring installation.
—End—
Procedure 6
Remove the BRSC, SILC, and UILC
Step Action
Perform the following steps to remove the BRSC, SILC, and the UILC.
1
Hold the card by its card-locking devices. Squeeze the tabs to
unlatch the card-locking devices and lift them away from the card.
2
Carefully disengage the BRSC, SILC, or UILC from the backplane
connector, and slowly slide the card from the module.
—End—
Procedure 7
Connecting ISDN BRI terminals to the system
Step Action
To connect the ISDN BRI terminals to the system, perform the following
steps.
1
Connect the system to the MDF.
2
Cross-connect the MDF.
3 Connect the ISDN BRI terminals to the Digital Subscriber Line (DSL).
—End—
Figure 5 "Connect the ISDN BRI terminals to the Large System" (page
24) shows a typical DSL with ISDN BRI terminals connected to it using
modular cables.
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 01.02 Standard