Network Card User's Manual
102 Testing ISDN BRI functions
2
After the call-or iginating ISDN BRI terminal receives an
acknowledgment that the receiving ISDN BRI terminal is ready, the
call-originating ISDN BRI terminal can begin transmitting packet
data.
3
Verify that the transmitted data has been received successfully
by checking the transmitted information for accuracy. Read the
information on the screen or print it on the local printer.
4
Perform this test between two ISDN BRI terminals on the same MPH
for local transmission and between a system ISDN BRI terminal
and a remote ISDN BRI terminal over the Packet Switched Data
Network (PSDN).
5 Release the connection.
—End—
Procedure 40
Perform a B-channel Switched Virtual Circuit packet data transmission test
using an MPH
Step Action
1
From an ISDN BRI B-channel packet data terminal, dial the Network
Terminal Numbers (NTNs) as configured in LD 27. Establish an
active call connection.
2
After the call-originating ISDN BRI terminal receives an
acknowledgment that the receiving ISDN BRI terminal is ready, the
call originating ISDN BRI terminal can begin transmitting packet data.
3 Verify that the transmitted data has been received successfully
by checking the transmitted information for accuracy. Read the
information on the screen or print it on the local printer.
4
Perform this test between two ISDN BRI terminals on the same MPH
for local transmission and between a system ISDN BRI terminal and
a remote ISDN BRI terminal over the packet data network.
5
Release the connection.
—End—
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318 01.02 Standard
Release 5.0 20 June 2007
Copyright © 2003-2007, Nortel Networks
.










