21 Click on the SipFwdAdapter tab. This tab allows the service
provider to set the valid events that the SIP Application Module
will process and determines whether or not the SIP Application
Server will or will not forward messages to a foreign server.
Figure 28 Completing the SipFwdAdapter tab fields
Table 21 SipFwdAdapter tab field descriptions (Sheet 1 of 2)
Field Value Description
maximumNumberOf
IdleContexts
Type=integer
Range=1-10000 numbers
Default=50
This is the maximum number
of idle contexts at any time. It
should not exceed the
maximum number of contexts.
initialNumberOf
Contexts
Type=integer
Range=1-10000 numbers
Default=10
This is the initial number of
contexts to create. It should
not exceed the maximum
number of contexts.
maximumNumberOf
Contexts
Type=integer
Range=1-10000 numbers
Default=5000
This is the maximum number
of contexts to create.