User's Manual

306 Appendix J Log descriptions
N0115791
Configuring what you want the BCM50a Integrated Router
to log
Use the sys logs load command to load the log setting buffer that is used to
configure which logs the BCM50a Integrated Router is to record.
Use sys logs category followed by a log category and a parameter to decide what
to record.
Use the sys logs save command to store the settings in the BCM50a Integrated
Router (you must do this in order to record logs).
Displaying logs
Use the sys logs display command to show all of the logs in the BCM50a
Integrated Router’s log.
Use the sys logs category display command to show the log settings for all of the
log categories.
Table 80 Log categories and available settings
Log Categories Available Parameters
access 0, 1, 2, 3
attack 0, 1, 2, 3
error 0, 1, 2, 3
ike 0, 1, 2, 3
ipsec 0, 1, 2, 3
javablocked 0, 1, 2, 3
mten 0, 1
upnp 0, 1
urlblocked 0, 1, 2, 3
urlforward 0, 1
Use 0 to not record logs for that category, 1 to record only logs for
that category, 2 to record only alerts for that category, and 3 to
record both logs and alerts for that category.