Remote Gateway 9150 Installation and Administration Guide 477
January 2005 Display log definitions
Statistic Definition
LOG NUMBER 91
DESCRIPTION This log indicates the status of a BRI module that has started (or
restarted) because of a system startup or manual restart.
SEVERITY WARNING
TASK BRI manager
PRODUCT 9150
CANCELLATION None
ACTION TO BE TAKEN Monitor the BRI module. If the cause is not a user-initiated reset, a
problem exists with either the BRI hardware or software. Try
replacing the BRI module, or swapping the BRI module with another
slot that shows no problem. If the problem persists, contact Nortel.
Note: MMI code (via MMI_SW_UPLD_LOG_ID) reports the status of
a BRI module restart resulting from an upload command.
PARAMETERS 1) BRI Module
2) Reset status (SUCCESS or FAILURE), activity leading to the error
(System Startup, User Reset)
DISPLAYED TEXT BRI #P1 boot status: P2