User manual

Remote Gateway 9150 Installation and Administration Guide 475
January 2005 Display log definitions
Statistic Definition
LOG NUMBER 87
DESCRIPTION This log indicates that a DSP has been taken Out Of Service. This
can occur for the following reasons:
1) Download or initialization failure (such as, at system startup)
2) Dynamic DSP failure with automatic recovery
3) User execution of the DSP restart debug command, which first
takes the DSP OOS, then tries to restart it
SEVERITY MAJOR (CRITICAL on 911x)
TASK VPM
PRODUCT RLC, 9150, 911x
CANCELLATION This action is followed by either log number 83 or 84, to indicate
reload SUCCESS or FAILURE, respectively.
ACTION TO BE TAKEN No action is required unless this results from DSP load failure (refer
to log number 84).
PARAMETERS 1) Single-digit DSP device ID
2) DSP module number
3) DSP device number
DISPLAYED TEXT DSP #P1 taken OOS. (Module, Device) = (P2, P3)
PRODUCES HOST PBX
ALARM AND ALERT
Yes