User manual

Nortel Secure Router 8000 Series
Configuration -WAN Access 4 POS and CPOS interface configuration
Issue 5.3 (
30 March 2009) Nortel Networks Inc. 4-33
Configuration files
z
For the low-speed CPOS interface, the configuration files are as follows:
Configuration file of Router A
#
sysname RouterA
#
controller Cpos3/0/1
clock master
e1 1 channel-set 1 timeslot-list 1-10
e1 1 set clock master
e1 2 channel-set 2 timeslot-list 11-15
e1 2 set clock master
e1 3 channel-set 3 timeslot-list 16-20
e1 3 set clock master
e1 4 channel-set 4 timeslot-list 21-30
e1 4 set clock master
#
interface Serial3/0/1/1:1
link-protocol ppp
ppp mp Mp-group 0/0/3
#
interface Serial3/0/1/2:2
link-protocol ppp
ppp mp Mp-group 0/0/3
#
interface Serial3/0/1/3:3
link-protocol ppp
ppp mp Mp-group 0/0/3
#
interface Serial3/0/1/4:4
link-protocol ppp
ppp mp Mp-group 0/0/3
#
interface Mp-group0/0/3
#
return
z
For the high-speed CPOS interface, the configuration files are as follow:
Configuration file of Router A
#
sysname RouterA
#
controller Cpos3/0/1
clock master
e1 1 unframed
e1 1 set clock master
e1 2 unframed
e1 2 set clock master
e1 3 unframed
e1 3 set clock master
e1 4 unframed
e1 4 set clock master
#