User manual

Installing and Maintaining the Versalar Switch Router 15000
3-12
308684-B Rev 00
Connecting to the DC Power Source
The Versalar 15000 supports two DC power supply modules. The second power
supply module provides redundancy. To operate in redundant mode, both circuit
breakers must be in the on (1) position.
When
operating with redundant DC input, the power source with the greater input
voltage provides power during normal operations, and the power source with the
lesser input voltage functions as the standby
.
Danger:
Due to high-energy hazards, only qualified service personnel are
permitted to connect the Versalar 15000 to the DC power source.
Danger:
Power to the input power cables must be disconnected before these
cables are connected or disconnected from the Versalar 15000.