User manual

Installing and Maintaining the Versalar Switch Router 15000
3-10
308684-B Rev 00
Removing a DC Power Module
If you are installing a second power module, go to “The DC Power Module” on
page 3-8
.
You can remove a power module with the power on or off.
To remove a power module:
1.
Remove the bottom front bezel.
2.
Using a flat-tip screwdriver, loosen the 2 captive screws that fasten the
power module to the chassis until the power module disengages
(Figure 3-6)
.
3.
Grasp the handle with both hands and pull the power module out of the
Versalar 15000.
You can remove an operational power module without affecting the operation
of the Versalar 15000. When you remove a power module, the LEDs on the
power module turn off, and the Versalar 15000 automatically redistributes the
load to the remaining power module.
4.
Install a new power module (see “The DC Power Module” on page 3-8) or
install a power filler module (see “Removing and Installing a Power Filler
Plate” on page 3-7).
Caution:
To maintain proper cooling, never operate the Versalar 15000 with
an empty power module slot. If you are replacing a failed second power
module and you do not have a power supply filler module, leave the failed
power module installed until a replacement power module is available.
Warning:
The sides of the power module are hot when you remove the power
module from a Versalar 15000 that has been operating recently. Hold the
power module by the bottom.