Computer Hardware Installation Guide

592 NT8D14 Universal Tr unk card
Figure 152
Ground start call connection sequence - incoming call from CO/FX/WATS
For outgoing calls from the Meridian 1, software sends an outgoing seizure
message to place a low-resistance loop across the tip and ring leads
toward the CO (see Figure 155 "Loop start call states - outgoing call to
CO/FX/WATS" (page 596) and Figure 156 "Loop start call connection
sequence - outgoing call to CO/FX/WATS" (page 597)). When the CO
detects the low-resistance loop, it prepares to receive digits.When the CO
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright © 2003-2008, Nortel Networks
.