BayStack User Guide

Installing the BayStack 350 Switch
304376-B Rev 00
2-3
Installation Procedure
This section provides the requirements and instructions for installing the
BayStack 350 switch on a flat surface or in a standard 19-inch utility rack. If you
install the switch in a rack, ground the rack to the same grounding electrode used
by the power service in the area. The ground path must be permanent and must not
exceed 1 ohm of resistance from the rack to the grounding electrode.
Installing the BayStack 350 Switch on a Flat Surface
The BayStack 350 switch can be mounted onto any appropriate flat, level surface
that can safely support the weight of a switch and its attached cables, as long as
there is adequate space around the unit for ventilation and access to cable
connectors.
Note:
An optional wall mount kit is available for the BayStack 350 switch.
See your Bay Networks sales representative for part number and ordering
information. Installation instructions are provided with the wall mount kit.
Caution:
When this device is installed in a stack on a shelf or tabletop, the
accumulated weight of the port cables increases with the height of the shelf or
tabletop.