Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis
If you need more help, go to the next section, “Diagnosing and correcting the
problem” on page 70.
4 POWER Indicator White/On steady Power indicator—The external DC power is
available to the BIP.
5 CRITICAL Indicator Red/On steady Critical fault indicator—Indicates that a severe
service-affecting condition has occurred that
requires immediate corrective action. Common
causes for this type of fault condition include:
• Line card failure
• Temperature fault
• CPU fault when only one CPU is installed
6 MAJOR Indicator Red/On steady Major fault indicator—Indicates that the system
hardware or software has identified a serious
disruption of service or that an important circuit
failure has occurred.
Common causes for this type of fault condition
include:
• CPU fault when two CPUs are installed
• Two fan trays are faulty
• A power supply circuit breaker has tripped due
to an overcurrent condition
• Two power supplies are faulty
7 MINOR Indicator Yellow/On steady Minor fault indicator —Indicates a problem that
does not have a serious effect on customer service,
or a problem in circuits that are not essential to
device operation.
Common causes for this type of fault condition
include:
• Shelf alarm cables not installed or not
connected properly.
• Alarm module jumpers configured incorrectly.
• One power supply is faulty
• One fan tray is faulty
Table 4 BIP LEDs and indicators (continued)