Ethernet Routing Switch Installation Guide

92 Installing Metro Ethernet Routing Switch 8600 modules and connecting equipment
Module Port
Connector
Recommended
cable type
Minimum
cable
length
Maximum
cable
length
OC-3 MT-RJ 9/125 µm
single-mode
fiber-optic cable
None 9.3 mi
(15 km)
8683POSM
OC-3
OC-3 MT-RJ 62.5/125 µm
multimode
fiber-optic cable
None 1.24 mi
(2 km)
OC-12 Duplex SC 9/125-µm
single-mode
fiber-optic cable
None 9.3 mi
(15 km)
8683POSM
OC-12
OC-12 Duplex SC 62.5/125 µm
multimode
fiber-optic cable
None 1640 ft
(500 m)
8683XLR 10GBase-
LR port
Duplex LC See Note 5 None See Note 5
8683XZR 10GBaseR
port
Duplex LC See Note 5 None See Note 5
Ethernet
Manage-
ment port
RJ-45 EIA Category 3,
4, or 5 UTP for
10 Mb/s operation;
EIA Category 5
UTP required
for 100 Mb/s
operation
8691omSF
Serial ports DB-9 RS-232
None 328 ft
(100 m)
Ethernet
Manage-
ment port
RJ-45 EIA Category 3,
4, or 5 UTP for
10 Mb/s operation;
EIA Category 5
UTP required
for 100 Mb/s
operation
8692omSF
Serial ports DB-9 RS-232
None 328 ft
(100 m)
Note 1: Ports on the 8632TXE, 8632TXM, 8648TXE, and 8648TXM modules are wired as MDI-X.
Use straight-through cables to connect these ports to MDI connections such as workstations or
servers. Use crossover cables to connect these ports to other MDI-X connections such as hubs or
other switches.
Note 2: Depends on installed GBIC model; for specifications, see Nortel Installation — SFP, XFP,
and GBIC Hardware Components (NN46225-301).
Note 3: Depends on installed SFP model; for specifications, see Nortel Installation — SFP, XFP,
and GBIC Hardware Components (NN46225-301).
Nortel Metro Ethernet Routing Switch 8600
Installation Modules
NN46220-306 02.02 Standard
4.2 7 July 2008
Copyright © 2005-2007, Nortel Networks
.