User's Manual
Page 56 of 332 Chapter 3 — System and site requirements
553-3021-209 Standard 3.00 April 2000
Table 11
AC input requirements for each NTDK91 and NTDK92 (North America)
Voltage
Recommended: 100-120 volts
Maximum limits: 90 and 132 volts
Single phase
Frequency
50-60 Hz
Power
(I/P max)
550 VA maximum
Outlet Type
120 volt, 15 Amp supply
Table 12
AC input requirements for each NTDK91 and NTDK92 (Europe and UK)
Voltage
Recommended: 208/220 volts
Maximum limits: 180 and 250 volts
Single phase
Frequency
50-60 Hz
Power
(I/P max)
550 VA maximum
Outlet Type
208/240 volt, 15 Amp supply
Note 1:
As local power specifications vary, see a qualified local electrician when
planning your power requirements.
Note 2:
The Supplied power must be single-phase 240 or three-phase 208 Y, and
must have a system ground conductor.