User's Manual
Chapter 15 — Installing and connecting SDI and Ethernet ports Page 201 of 332
Option 11C Mini Planning and Installation Guide
Terminal setup
The terminal can be setup any time, except during data transmission. Do not
set up the terminal during data transmission to avoid potential data loss.
Table 46 on page 203 and Table 48 on page 205 provide setup values. Use
Procedure 25 to set up the terminal.
Procedure 25
Setting up the terminal
1 Turn on the power for the terminal.
2 Enter setup mode by pressing the <SETUP> key located on the
top row of the special function keys.
The terminal screen displays the current setup values.
Table 44
NTAK03 connections at the cross-connect terminal — Port 1
Pair Color Signal
Designations
(I=input,
O=output)
6T
6R
R-BL
BL-R
DSR
-
I
-
7T
7R
R-O
O-R
-
DTR
-
O
8T
8R
R-G
G-R
RTS
CTS
O
I
11T
11R
BK-BL
BL-BK
RX
TX
I
O
13T
13R
BK-G
G-BK
-
DCD
-
I
22T
22R
V-O
O-V
SG
-
O
-