Page 178 of 332 Chapter 13 — Installing and connecting the cross-connect terminal
553-3021-209 Standard 3.00 April 2000
3 Attach labels on the cross-connect terminal to indicate the terminal
blocks assigned to the following:
Analog line cards
DC15/AC15/RAN/PAG cards
Data Access cards
AUX wiring
Power Failure Transfer Units
Digital line cards
Telephones and Attendant Consoles
Exchange line trunk cards
Direct Dialing Inward trunk cards
miscellaneous equipment
—————————— End of Procedure —————————
Connecting the cables
Each Option 11C Mini system chassis requires up to five 25-pair cables. The
Main Chassis requires an additional terminal block at the cross-connect
terminal to terminate the 9-pin conductor auxiliary cable.
Connect all cables at the back of the chassis.
Note:
Use caution when using NE-A25B cables with the NTAK02, and
NTAK03 cards. These cables are not wired out to station equipment or
trunk circuits. Do not use the NE-A25B cable with the NTBK45,
NTAK10, NTBK50, or NTAK79 circuit cards.
WARNING
Always use caution when installing or modifying telephone lines. Do
not install telephone wiring during a lightning storm. Never touch
uninsulated telephone wiring unless the line is disconnected at the
network interface.