Server User Manual
Page 88 of 488 Rack-mounting the components
553-3041-210 Standard 4.00 September 2007
1 Attach the rack-mount brackets (“B” as shown in Figure 19 on page 83) to
the equipment rack. Install the left and right side at an equal height. Use
standard length screws from the accessories pouch, and screw them into
the top and bottom drill holes of the bracket (see Figure 24 on page 88).
Figure 24
Installed rack-mount bracket
2 When both brackets are fixed in place:
a. Align the rack-mount brackets on the Signaling Server with the slide
rail system on the rack posts.
b. Slide the Signaling Server in place. Refer to Figure 25 on page 89.
WARNING
MAIN AC POWER DISCONNECT
A main AC power disconnect must be installed. The main
AC power disconnect must:
• disconnect power to the entire rack unit
• be readily accessible
• be labeled as controlling power to the entire unit, not
just to the Signaling Server(s)