Server User Manual
Configuring MG 1000T survivability and alternate primary controller Page 473 of 488
Communication Server 1000E Installation and Configuration
5 Configure the SWOTO.
Configure the SWOTO separately for each MG 1000T Expansion.
The SWOTO command is configured in LD 117:
CHG SWOTO <cab#> <value>
• cab# = 1-4, MG 1000T Expansion
•value = 2 - (120) - 600 seconds
For point-to-point connection (MG 1000T Expansions that are not
connected over a LAN), Nortel recommends that you set the timer to a low
value to minimize service interruption.
End of Procedure
Printing Survivable MG 1000T Expansion parameters
The following Print commands, available in LD 117, print the MG 1000T
Expansion parameters and Survivability for all, or specified, Survivable
MG 1000T Expansion.
PRT SURV cab
Where:
cab = 1 to 4,
MG 1000T Expansion
PRT CAB cab
Where:
cab = 1 to 4,
MG 1000T Expansion
Configuring Alternate primary controller
Procedure 120
Configuring the IP telephony node for Alternate primary controller
1 Log in to Element Manager, if you are not already logged in.
2 Select IP Telephony > Nodes: Servers, Media Cards > Configuration
from the navigator.
The Node Configuration web page opens, as shown in Figure 99 on
page 322.