Server User Manual
Page 380 of 488 Configuring an IP telephony node
553-3041-210 Standard 4.00 September 2007
The Follower Signaling Server attempts to FTP the BOOTP.TAB file from
the node master (Leader Signaling Server).
Note: Since the Follower cannot obtain the system login and password,
the FTP fails (for first-time Follower Signaling Server installation only). It
does not have the current CONFIG.INI file that contains the CS 1000E IP
address. Subsequent FTPs succeed.
6 Transfer the node files again, so that the Follower Signaling Server
obtains a copy of CONFIG.INI.
7 Reboot the Follower Signaling Server so that all its applications can start
based on the new CONFIG.INI file.
The Signaling Server uses BootP to obtain its network data, and it then
FTPs the BOOTP.TAB file from the node master (Leader Signaling
Server).
End of Procedure
Performing a datadump
Follow Procedure 97 to perform a datadump using Element Manager. This
procedure is an alternative to using CLI to perform a datadump. The
datadump backs up new IP Telephony node files on the CS 1000E at the same
time that it backs up the customer database.
Procedure 97
Performing a datadump using Element Manager
From within Element Manager (see Figure 93 on page 370 for details on
logging in), do the following:
1 Choose Services > Backup and Restore > Call Server from the
navigator.
2 The Call Server Backup and Restore web page opens, as shown in
Figure 80 on page 223.