2 The COM port on the PC Maintenance terminal should be set as follows:
Terminal type: VT100
Speed: 19200
Data bits: 8
Parity: none
Stop bits: 1
Flow control: none
After the installation, the Signaling Server maintenance port speed can be
changed. See Signaling Server: Installation and Configuration
(553-3001-212).
End of Procedure
BayStack 470 SDI connection
The SDI port on the Bay Stack 470 can be used for basic configuration and
maintenance. The SDI port is located on the faceplate. It is a DCE port with
a default speed of 9600 bps.
Media Card SDI connection
The SDI ports on a Media Card can be used for basic configuration or
maintenance. Figure 91 shows the maintenance port location on the Media
Card and the Shielded 50-pin to Serial/ELAN/TLAN adapter.