Server User Manual
Connecting a Terminal Server Page 255 of 488
Communication Server 1000E Installation and Configuration
• Procedure 65: "Accessing a CS 1000E from a PC through telnet
Terminal Server" on page 259
• Procedure 66: "Configuring a transparent rlogin port" on page 260
• Procedure 68: "Accessing an MRV Console Port through the
on-board modem" on page 264
Configuring a Terminal Server
Follow Procedure 62 to connect a Terminal Server with a CS 1000E system.
Table 14 lists the MRV cables required to install the IR-8020M-101 Terminal
Server in a CS 1000E system.
Customer-made cables with the following pin out (as NTDU6302) can also
be used. See Table 15.
Table 14
Required MRV serial cables and connectors
Order Code Description
NTDU6302 Connects MRV Terminal Server to any
standard DTE port or DCE port when a Null
modem is used
NTDU6303 Used for telnet, rlogin connections
P/N-151-3028 Male RJ-45 to Male RJ-45 with connectors,
10 feet
P/N-350-0308 Female RJ-45 to Female DB9
Table 15
Customer made cable pin out
Pins on DB9 Female Pins on RJ45 Male (MRV Terminal Server)
1
6
DCD
DSR
2 DTR
2 RXD 3 TxD