Server User Manual

Installing and configuring the Signaling Server software Page 191 of 488
Communication Server 1000E Installation and Configuration
Figure 70
Stand-alone Signaling Server configuration
14 Enter the Primary NRS IP address or the Alternate NRS IP address,
depending on the option entered in step 11 on page 187 or step 12 on
page 188.
•If b was entered in step 12, enter the address of the Primary NRS.
See Figure 71 on page 192.
•f a was entered in step 12, you can enter the address of the Alternate
NRS if you know it, but it is not required. See Figure 72 on page 192.
•If c was entered in step 12:
Enter the address of the Primary NRS. See Figure 71.
Enter the address of the Alternate NRS. See Figure 72.
•If d was entered in step 11:
Enter the address of the Primary NRS (optional). See Figure 71.
If you did enter the address of the Primary NRS, enter the
address of the Alternate NRS (also optional). See Figure 72.
The Gatekeeper configuration can be updated later using Element
Manager.
CS 1000 Signaling Server Software Install Tool (sse-x.xx.xx)
=====================================================================
Please define the data networking parameters for this Standalone
Signaling Server. Note that the ELAN parameters are necessary for
Hostname : SS_SA
TLAN IP : 192.168.20.20
TLAN subnet mask: 255.255.255.0
TLAN gateway IP : 192.168.20.1
management access (e.g. SNMP).
ELAN IP : 192.168.10.20
ELAN subnet mask: 255.255.255.0
ELAN gateway IP : 192.168.10.1