Server User Manual

Page 148 of 488 Installing software on the CS 1000E
553-3041-210 Standard 4.00 September 2007
From active Call Server 1, perform the following tests on Call Server 0:
1 Perform a redundancy sanity test:
2 Check the LCD states
a. Perform a visual check of the LCDs.
b. Test and LCDs:
c. Check that the LCD display matches the software check.
3 Test the System Utility card
4 Test system redundancy and media devices:
5 Clear the display and minor alarms on both Call Servers:
6 Check dial tone.
LD 135
STAT CPU Get status of CPU and memory
TEST CPU Test the CPU
LD 135
TEST LEDs Test LEDs
DSPL ALL
LD 135 Load program
STAT SUTL Get the status of the System Utility card
TEST SUTL Test the System Utility card
LD 137 Load program
TEST RDUN Test redundancy
DATA RDUN Test database integrity
STAT FMD Status of one or both Fixed Media Devices
(FMD)
STAT RMD Status of one or both Removable Media Devices
(RMD)
LD 135 Load program
CDSP Clear the displays on the cores
CMAJ Clear major alarms
CMIN ALL Clear minor alarms