Connecting CS 1000E system components Page 111 of 488
Communication Server 1000E Installation and Configuration
Procedure 15
Connecting an MG 1000E in the Dual Homed configuration
1 Connect logical port 2 of the MG 1000E 100BaseT daughterboard #2 to
the bulkhead connector #2. Connect the 100BaseT Port 2 at the back of
the Media Gateway to a second BayStack 470.
For CS 1000E systems, it is recommended that there be no single point of
failure for the data network. For information on engineering the data network,
refer to Converging the Data Network with VoIP (553-3001-160).
End of Procedure
Connecting a Signaling Server to the ELAN subnet
Follow Procedure 16 to connect a Signaling Server to the ELAN subnet.
Procedure 16
Connecting a Signaling Server to the ELAN
1 Connect one end of a standard CAT5 cable to the ELAN network interface
(bottom) at the back of the Signaling Server, as shown in Figure 33 on
page 112.
2 Connect the other end of the standard CAT5 cable to an RJ-45 ELAN
subnet port on the ELAN Layer 2 switch (BayStack 470-24T).