Owner's manual
906 NTCK16 Generic Central Office Trunk cards
Pad switching
The NTCK16AX and NTCK16BX generic Central Office trunk cards
support the North American loss plan. Software configuration allows the
selection of 4 dB loss pads on a per unit basis.
Table 388
NTCK16 pad switching
Loss Analog-to-Digital Digital-to-Analog
PAD out 0 dB –3 dB
PAD in +4 dB +1 dB
Note:
The tolerance for the above nominal values is +0.3 dB, -0.7 dB.
Connector pin assignments
Cross connections
Figure 258 "NTCK16 Central Office trunk connections for NT8D37 I/O
panel connectors A, E, K, R" (page 907), Figure 259 "NTCK16 Central
Office trunk connections for NT8D37 I/O panel connectors B, F, L, S"
(page 908), and Figure 260 "NTCK16 Central Office trunk connections
for NT8D37 I/O panel connectors C, G, M, T" (page 909) provide cross
connect information for the NTCK16AX and NTCK16BX generic Central
Office trunk cards.
Configuration
The trunk type for each unit on the card is selected by software service
change entries at the system terminal.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.