Owner's manual

902 NTCK16 Generic Central Office Trunk cards
The cards listed below are minimum vintage required to support the
following countries:
NTCK16AA generic Central Office trunk card with PPM
Ireland
NTCK16BC generic Central Office trunk card without PPM.
Brazil
Ireland
Mexico
Tortolla
Singapore
NTCK16AD generic Central Office trunk card with PPM
Turkey
NTCK16BD generic Central Office trunk card without PPM.
Argentina
Turkey
Brazil
Chile
Indonesia
Korea
Venezuela
Throughout this chapter, cards with PPM are identified by the vintage AX.
Cards without PPM are referenced by the vintage BX.
Physical description
The NTCK16AX and NTCK16BX generic Central Office trunk cards uses
eight units. Each unit connects to the shelf backplane through an 80-pin
connector. The backplane is cabled to the I/O panel which is then cabled
to the cross-connect terminal. At the cross-connect terminal, each unit
connects to external apparatus by Tip and Ring leads.
Switch settings
There are no option switches on the NTCK16AX and NTCK16BX generic
Central Office trunk cards. All settings are configured in software.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008