748 NTAK02 SDI/DCH card
Table 302
Switch settings
Port 0 Port 1
SW 1-1 SW 1-2
SDI (not supported) DCH OFF OFF
SDI (not supported) DCH OFF ON
—
ESDI ON ON
Port 2 Port 3
SW 1-3 SW 1-4
SDI (not supported) DCH OFF OFF
SDI (not supported) DCH OFF ON
—
ESDI ON ON
Note: Digital Private Network Signaling System DPNSS can replace
the DCH function in the U.K.
Two ports offer the option for DTE/DCE configuration. This option is
selected from a jumper on the card. Table 303 "Jumper settings" (page
748) shows the jumper settings.
Table 303
Jumper settings
Port
Jumper
location
Strap for
DTE
Strap for
DCE
Jumper
location RS422 RS232
0
J10 C - B B - A
1
J7
J6
C-B
C-B
B-A
B-A
J9
J8
C-B
C-B
B-A
B-A
2
J5 C - B B - A
3
J4
J3
C-B
C-B
B-A
B-A
J2
J1
C-B
C-B
B-A
B-A
Connecting to the ports
External devices are connected to the SDI/DCH card by the following:
• the NTAK19FB four-port SDI cable. This cable does not have to be
terminated at the cross connect terminal since it is equipped with
connectors.
• the NE-A25-B cable. Terminate the NE-A25-B cable at the cross
connect terminal. Tables Table 304 "NTAK02 pinouts - Port 0 at the
cross-connect terminal" (page 749) through Table 307 "NTAK02
connections at the cross-connect terminal - Port 3" (page 750) give
the pinouts for the SDI/DCH card.