Owner's manual

726 NT8D41BA Quad Serial Data Interface Paddle Board
Table 286
NT8D41BA baud rate switch settings
SW13 (port 1), SW10 (port 2),
SW11 (port 3), SW12 (port 4)
Baud rate
Baud Clock
(kHz) 1234
150 2.40
on
off
on on
300 4.80
on on
off
on
600 9.60
on
off off
on
1,200 19.20
on on on
off
2,400 38.40
on
off
on
off
4,800 76.80
on on
off off
9,600 153.60
on
off off off
19,200*
307.20
on on on on
* For future use.
Table 287
NT8D41BA address switch settings
SW15
Port 1 Port 2
Switch settings
SW16
Port 3 Port 4 1* 2
+
34
5
6
7
8
01
E X off off off off off off
Device
23
E X off off off off off
on
4
5
E X off off off off
on
off
pair
6
7
E X off off off off
on on
89
E X off off off
on
off off
addresses
10 11
E X off off off
on
off
on
12 13
E X off off off
on on
off
14 15
E X off off off
on on on
* To enable ports 1 and 2, set SW15 position 1 to ON. To enable ports 3 and 4, set SW16
position 1 to ON.
+
For each X, the setting for this switch makes no difference, because it is not used.
Address
Switch SW15 or SW16 and logic on the card always address the four
UARTs using a pair of addresses: 0 and 1, 2 and 3 through 14 and 15.
The settings for both switches are shown in Table 288 "NT8D41BA
address switch settings" (page 727). To avoid system problems,
switches SW15 and SW16 must not be configured identically. Figure 246
"NT8D41BA QSDI paddle board" (page 723) displays SW15 and SW16.