674 NT8D15 E and M Trunk card
the far-end may start pulsing after the standard delay (normally 70
ms minimum).
In delay dial mode, a 256–384 ms off hook/on hook signal is
returned to the far-end immediately after receipt of the seizure
signal. When the far-end detects the on hook state of the signal
(the start signal), the far-end may start pulsing after the standard
delay (normally 70 ms minimum).
In wink start mode, within a 128–256 ms period after receipt of the
seizure signal from the far-end, the called office transmits a 250
ms, wink start, off hook/on hook signal to the calling office.
Table 245
Operation mode
Operation mode Start arrangement
Immediate start IMM
Delay dial DDL
Wink start WNK
The far-end initiates calls as follows:
The ground is placed on the E lead in E and M signaling.
Dial pulses are subsequently applied from the far-end as ground open
on the E lead.
If the far-end is equipped for sending, the system can operate in any
mode (immediate start, delay dial, or wink start), as assigned on a start
arrangement basis. See Table 246 "Operation Mode" (page 675).
In immediate start mode, there is no start signal from the called
office. The seizure signal (off hook supervisory state) from the
far-end should be at least 150 ms. At the end of the seizure signal,
the far-end can start pulsing after the standard delay (normally 70
ms minimum).
In delay dial mode, a 256–384 ms off hook/on hook signal is
returned to the far-end immediately after receipt of the seizure
signal. When the far-end detects the on hook signal (start signal),
the far-end can start pulsing after the standard delay (normally 70
ms minimum).
In wink start mode, within a 128–256 ms period after receipt of the
seizure signal from the far-end, the called office transmits a 250
ms, wink start, off hook/on hook signal to the calling office.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008