Owner's manual
Connector pin assignments 439
Table 178
NT8D02 Digital Line Card - environmental specifications
Parameter
Specifications
Operating temperature
0
to +60
C (+32 to +140
F), ambient
Operating humidity 5 to 95% RH (non-condensing)
Storage temperature
–40
to +70
C (–40
to +158
F)
Connector pin assignments
Table 179 "NT8D02 Digital Line card - backplane pinouts" (page
439) shows the I/O pin designations at the backplane connector, which
is arranged as an 80-row by 2-column array of pins. Normally, these pin
positions are cabled to 50-pin connectors at the I/O panel in the rear of
each module for connection with 25-pair cables to the MDF.
The information in Table 179 "NT8D02 Digital Line card - backplane
pinouts" (page 439) is provided as a reference and diagnostic aid at the
backplane, since the cabling arrangement can vary at the I/O panel. See
Communication Server 1000M and Meridian 1 Large System Installation
and Configuration (NN43021-310) for cable pinout information for the I/O
panel.
Table 179
NT8D02 Digital Line card - backplane pinouts
Backplane
Pinout*
Lead
Designations
Backplane
Pinout*
Lead
Designations
12A Line 0, Ring 12B Line 0, Tip
13A Line 1, Ring 13B Line 1, Tip
14A Line 2, Ring 14B Line 2, Tip
15A Line 3, Ring 15B Line 3, Tip
16A Line 4, Ring 16B Line 4, Tip
17A Line 5, Ring 17B Line 5, Tip
18A Line 6, Ring 18B Line 6, Tip
19A Line 7, Ring 19B Line 7, Tip
62A Line 8, Ring 62B Line 8, Tip
63A Line 9, Ring 63B Line 9, Tip
64A Line 10, Ring 64B Line 10, Tip
65A Line 11, Ring 65B Line 11, Tip
66A Line 12, Ring 66B Line 12, Tip
*These pinouts apply to both the NT8D37 and NT8D11 backplanes
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.