Owner's manual

Maintenance 403
Figure 105
MSDL states
A newly configured MSDL automatically enters the manually disabled
state. An operating MSDL can be manually disabled by issuing the DIS
MSDL x command in LD 37 (step 1 in Figure 105 "MSDL states" (page
403)).
Entering the DIS MSDL x command in LD 37 moves the card to manually
disabled status and stops all system communication with the card (step 5
in Figure 105 "MSDL states" (page 403)).
Manually enabled
When the card has been manually disabled, re-enable it with the ENL
MSDL x command in LD 37 (step 2 in Figure 105 "MSDL states" (page
403)).
System disabled
When the system disables the MSDL card (step 4 in Figure 105 "MSDL
states" (page 403)), it continues to communicate and attempt maintenance
procedures on the card. To stop all system communication with the
card, enter DIS MSDL x to disable it (step 5 in Figure 105 "MSDL states"
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008