Owner's manual
Architecture 345
Use Table 146 "Switch setting for MSDL external card" (page 345) to set
the card address.
Table 146
Switch setting for MSDL external card
Switch Setting
DNUM (LD 17) 1 2 3 4
0
OFF OFF OFF OFF
1
ON OFF OFF OFF
2
OFF ON OFF OFF
3
ON ON OFF OFF
4
OFF OFF ON OFF
5
ON OFF ON OFF
6
OFF ON ON OFF
7
ON ON ON OFF
8
OFF OFF OFF ON
9
ON OFF OFF ON
10
OFF ON OFF ON
11
ON ON OFF ON
12
OFF OFF ON ON
13
ON OFF ON ON
14
OFF ON ON ON
15
ON ON ON ON
Architecture
Clock operation
There are two types of clock operation - tracking mode and free-run mode.
Tracking mode
In tracking mode, the DDP2 loop supplies an external clock reference to
a clock controller. Two DDP2 loops can operate in tracking mode, with
one defined as the primary reference source for clock synchronization,
the other defined as the secondary reference source. The secondary
reference acts as a back-up to the primary reference.
As shown in Figure 95 "Clock Controller primary and secondary tracking"
(page 346), a system with dual CPUs can use two clock controllers (CC-0
and CC-1). One clock controller acts as a back-up to the other. The clock
controllers should be completely locked to the reference clock.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008