Owner's manual
224 NT5D11 and NT5D14 Lineside T1 Interface cards
Table 89
MMI commands and command sets (cont’d.)
Command
Description
DC
Display Configuration
Displays the configuration settings for the cards including:
•
the serial number of the card
•
MMI firmware version
• date and time
•
alarm enable/disable setting
• self-clearing enable/disable setting
•
settings entered in Set Configuration
•
dip switch settings
D H [P]
Display History [Pause]
Displays performance counters for the past 24 hours.
DP
Display Performance
Displays performance counters for the current hour.
D S [P]
Display Status [Pause]
Displays carrier status, including whether the card is in the alarm state, and
what alarm level is currently active.
H or ? Help
Displays the help screen.
L Login
Logs into the MMI terminal when the system has one Lineside T1 card.
Q
Quit
Logs the terminal user out. If multiple Lineside T1 cards share a single
terminal, logout after using the MMI. Because of the shared daisy-chained link,
if a Lineside T1 card is logged in, it occupies the bus and no other Lineside T1
cards are able to notify the MMI of alarms.
SA
Set Alarm parameters
Alarm parameters include the allowable bit errors per second threshold and
alarm duration.
SC
Set Clearing
Sets the alarm self-clearing function to either enable or disable.
SD
Set Date
Sets date or verifies current date.
ST
Set time
Sets time or verifies current time.
T x Test
Initiates the T1 carrier test function. To terminate a test in process, enter the
STOP TEST (S) command at any time.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008